1.
Artigo em Inglês | MEDLINE | ID: mdl-38449460

RESUMO

Background: Transcutaneous osseointegration for amputees (TOFA) has proven to consistently, significantly improve the quality of life and mobility for the vast majority of amputees, as compared with the use of a socket prosthesis1,2. As with any implant, situations such as infection, aseptic loosening, or implant fracture can occur, which may necessitate hardware removal. Although it may eventually occur, to date no osseointegration implant has ever required removal in the setting of periprosthetic fracture. Since TOFA implants are designed to facilitate robust bone integration, removal can be challenging. Even in cases in which portions of the implant are loose, other areas of the implant may remain strongly integrated and resist removal. Further, there can be cases in which an implant fractures, leaving the residual portion of the implant in place without the interface for an extraction tool. Although the outcomes of revision osseointegration has not been the primary focus of any publication, the fact that revision can be necessary and generally succeeds in restoring similar mobility has been documented3-5. As with any hardware removal, preserving healthy tissue and avoiding iatrogenic injury are critically important. This article demonstrates several techniques to remove press-fit osseointegration implants that we have found safe and effective. Description: The procedure is performed with the patient in the supine position and with the affected extremity prepared and draped in a typical sterile fashion. The use of a tourniquet can help reduce blood loss, but it may be safer to not use a tourniquet during the portions of the procedure that create increased or prolonged bone thermal exposure, such as during reaming or drilling. If patients are clinically stable, withholding antibiotics until cultures are obtained may improve diagnostic yield. The implant removal technique should proceed from conservative to aggressive, as necessary: slap hammer, thin wire-assisted slap hammer, and extended osteotomy. Trephine reaming is discouraged because of the need for and difficulty of removing the dual cone interface portion of the implant, along with the extensive damage often caused to the surrounding bone during reaming, which can be avoided with the osteotomy technique. Alternatives: It is important to emphasize that most infections related to transcutaneous osseointegration do not require implant removal; the use of antibiotics alone or soft-tissue and/or limited bone debridement is sufficient to resolve infection in the majority of cases. If a patient has a non-infectious indication for removal (such as a loose implant) but declines surgery, activity modification with close observation may be reasonable. If a patient has an infectious indication for removal but declines surgery, very close observation must be maintained to avoid potential osteomyelitis. The use of suppressive antibiotics (oral and/or intravenous) may help reduce the severity of the infection. An alternative surgery to manage implant-associated infection can be amputation above the implant (within the same bone, through-joint amputation, or through the femur for a transtibial osseointegration). This should be considered only if there is a tremendously compelling reason to do so, such as an emergency need to amputate due to a life-threatening infection. Rationale: Indications for implant removal include persistent pain, deep infection recalcitrant to soft-tissue or bone debridement and implant retention, or mechanical complications involving the implant, such as loosening or breakage. The following are specific examples of indications for removal: infection that cannot be resolved with oral and/or intravenous antibiotics or with debridement of soft tissue and/or bone, implants that have not achieved or not maintained stable integration (aseptic or loosening) and are causing pain, and implants that have fractured or have deformed and are a concern for fracture. Expected Outcomes: Most patients who require removal of press-fit osseointegration implants are suitable for reimplantation after a decontamination period involving a local antibiotic depot and intravenous antibiotics. This duration is often 6 to 12 weeks. Following revision osseointegration, patients generally achieve similar levels of performance as they had during the stable period prior to removal3-5. Infection does not appear to be associated with an increased risk of mortality6. Patients who decline revision osseointegration are able to return to the use of a socket prosthesis. Important Tips: Infection is often treatable with use of oral and/or intravenous antibiotics, with or without soft-tissue and/or bone debridement. Consider these options before reflexively removing an implant.Preserving bone stock and quality is important for an optimal revision to another osseointegration prosthesis or conversion to a socket prosthesis. Living bone, even if infected, can be decontaminated with antibiotics. Minimize thermal injury by releasing the tourniquet and using saline solution irrigation during reaming or similar portions of the procedure. If the implant can only be removed by fully removing a portion of bone (rather than through a single clamshell-type osteotomy), attempt screw osteosynthesis to preserve a canal for future osseointegration.Be gentle and patient during the removal techniques. Elevating bone quickly or violently may cause propagating fractures, increased morbidity, or splinter bone fragments. Carefully separating bone from implant will reduce bone loss and preserve the bone condition for a potential revision.Although patients may not appear to have an infection in some cases, it is advised to treat every removal as if it involves an infection. The first surgical stage should be for removal, culture acquisition, and decontamination with antibiotics. A separate second surgery can be performed after the antibiotics have eradicated infection.Many implants have been removed with slap hammer or fine wire techniques; osteotomy should be reserved for situations in which diligent attempts using these techniques have proven unsuccessful, in order to optimize bone integrity.

2.
Ophthalmic Surg Lasers Imaging Retina ; 48(4): 319-325, 2017 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-28419397

RESUMO

BACKGROUND AND OBJECTIVE: To evaluate the repeatability, reliability, and comparability of macular thickness measurements between three optical coherence tomography (OCT) machines in healthy eyes, eyes with diabetic macular edema (DME), and eyes with neovascular age-related macular degeneration (nAMD). PATIENTS AND METHODS: Twenty-three eyes with DME, 26 eyes with nAMD, and 24 healthy eyes as controls were evaluated. Scans were performed using the swept-source Triton (Topcon, Tokyo, Japan), the spectral-domain Cirrus (Carl Zeiss Meditec, Dublin, CA), and the Spectralis (Heidelberg Engineering, Heidelberg, Germany) machines. Scans were evaluated for central macular thickness (CMT), presence of segmentation and fixation imaging artifacts (IA), re-scan reliability, and agreement between machines and groups. RESULTS: Mean CMT was significantly different between all OCT machines in all groups (P < .01 for all comparisons). Manually correcting IA did not alter these results. There was good scan repeatability among healthy and DME eyes for each machine, but poor repeatability among the nAMD group with the Spectralis (P = .038). IA were significantly increased in the presence of pathology. CONCLUSIONS: There is poor agreement of CMT measurement between OCT machines in healthy eyes and those with DME and nAMD. DME and nAMD have a significant effect on the rate of IA in scans. Care is required when interpreting measurements from different OCT devices in clinical practice and research settings. [Ophthalmic Surg Lasers Imaging Retina. 2017;48:319-325.].


Assuntos
Algoritmos , Retinopatia Diabética/diagnóstico , Degeneração Macular/diagnóstico , Edema Macular/diagnóstico , Retina/patologia , Tomografia de Coerência Óptica/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Feminino , Humanos , Macula Lutea/patologia , Masculino , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...